Description

The nonlinear controller data file contains parameters that define the controller settings and performance. In addition to control gains, the data file describes upper and lower limits on output signals, floating feedback control settings, and reference values for wind turbine operation.

The nonlinear controller regulates rotor speed and output power for fixed-based or floating wind turbines by actuating blade pitch and generator torque. The control operation can be divided into 2 regimes:

  • Regime 2: Wind speed is below the rated value, so control focuses on maximizing power extraction.
  • Regime 3: Wind speed is above the rated value, so control focuses on maintaining the rated rotor speed and power.

Parameters

Name Description Value Unit
Pref Reference power. Real scalar [W]
UlowHysteresis Low hysteresis threshold of the regime switching logic. Real scalar [rad/s]
UhighHysteresis High hysteresis threshold of the regime switching logic. Real scalar [rad/s]
Kt Gain value of torque controller. Real scalar [N.m.s²/rad²]
R3TorqueKgain Torque gain for regime 3. Real scalar [W.s/rad]
TorqueMin Minimum value of output torque. Real scalar [N.m]
TorqueMax Maximum value of output torque. Real scalar [N.m]
TorqueMinRate Minimum value of output torque rate. Real scalar [N.m/s]
TorqueMaxRate Maximum value of output torque rate. Real scalar [N.m/s]
Kp2Pitch Proportional gain of pitch controller in regime 2. Real scalar [1/s]
Kp3Pitch Proportional gain of pitch controller in regime 3. Real scalar [s²/rad]
Ki3Pitch Integral gain of pitch controller in regime 3. Real scalar [s/rad]
LowerBeta Minimum value of output blade pitch. Real scalar [rad]
UpperBeta Maximum value of output blade pitch. Real scalar [rad]
BetaMinRate Minimum value of output pitch rate. Real scalar [rad/s]
BetaMaxRate Maximum value of output pitch rate. Real scalar [rad/s]
FloatEnable Enable the floating feedback control. Boolean (0/1) [0/1]
FloatKp Proportional gain of floating feedback controller. Real scalar [-]
FloatLPFOrder Order of the low-pass filter. Positive integer [-]
FloatLPFCutoff Cut-off frequency of the low-pass filter. Real scalar [Hz]
FloatHPFOrder Order of the high-pass filter. Positive integer [-]
FloatHPFCutoff Cut-off frequency of the high-pass filter. Real scalar [Hz]

Notes

The nonlinear controller data is stored in a .txt file that can easily be produced using the Data Generation Tool or by populating a .txt file manually. If the file is created manually, parameters must be defined in the format name = value;, where name is the parameter name and value is a number of type Real (although booleans expressed as 1 or 0 and integers are still accepted). Comments can be inserted in the file using double slash: //. See below for an example.


    // =============================================
    // Inertial properties
    // =============================================
    m = 123.456; // mass [kg]
    I_xx = 1.23e4; // mass moment of inertia [kg.m²]

    // =============================================
    // Geometric properties
    // =============================================
    l = 12.345; // length [m]

The block diagram illustrates the control algorithm of the nonlinear controller. The control algorithm switches between regime 2 and regime 3 based on the switching condition. To ensure a smooth transition between the two, a setpoint smoother block is integrated with the switching logic to avoid abrupt changes during the transition.